• SKU: A320S3-3
• Input phase: 1 phase
• Input voltage: 200 - 240V
• Input frequency: 50/60Hz
• Control method: V/F, SVC
• Braking resistor: not required
• Size: 216*101*151mm
• Output phase: 3 phase
• Output voltage: 0 - 220V
• Output frequency: 0 - 400Hz
• Output current: 0 - 13.0A
• Output power: 0 - 3kW (4HP)
• R, S, T: power source, three-phase 220V
• U, V, W: connected to your motor for driving
• PE: Grounding
• AVI: 0-10 signal input
• ACI: 4-20mA analog input
• 10V: power supply for setting potentiometer
• AO: Analog output signal, set by parameter F6.10
• GND: 0 potential, common terminal for input and output signals
• X1: Digital input, set by parameter F5.02, the default value is "forward"
• X2: Digital input, set by parameter F5.03, the default value is "reverse"
• X3: Digital input, set by parameter F5.04, the default value is "multi-speed first"
• X4: Digital input, set by parameter F5.05, the default value is "multi-speed second"
• X5: Digital input, set by parameter F5.06, the default value is "external reset signal"
• TA, TB, TC: relay output, set by parameter F5.07, capacity AC 250V/3A or DC 24V/2A
• PRG/SET: it is used to read and modify parameters; press it to enter the parameter group or display the parameter value
• JOG/ESC: it is used for jog operation of VFD or return of parameter setting
• UP/DOWN: the keys for value modification
• RUN: in panel mode, it is the key used to start the VFD
• STOP/RES: in panel mode, it is the key used to stop the VFD
• Speed knob: control the value of frequency and motor speed
• Display screen: show the current status or parameter values
• Parameter F0.02=0
• Press the green button "RUN" to start the motor, and press the red button "STOP" to stop the motor.
• The motor runs forward by default, if you want to reverse the motor, please realize it through the following ways.
• X1 on, motor forward • X2 on, motor reverse • X1 or X2 off, motor stops.
• Parameter F0.02=1
• X1 on, motor forward • X2 on, motor reverse • X1 or X2 off, motor keeps running • X3 off, motor stops working
• Parameter: F0.02=1, F5.04=5, F5.00=2
• Parameter F0.03 sets the way to adjust the VFD output frequency
• The default value is 4, and the frequency is adjusted by the Speed Knob on the control panel
• When the value is 2, the frequency is adjusted by AVI input (0-10V)
• When the value is 3, the frequency is adjusted by ACI input (4-20mA)
• When the value is 1, the frequency is adjusted by UP/DOWN, and each step is Parameter F0.07