476HP VFD Three Phase 380V Efficient Motor Operation and Control 355kW

SKU:

A720HG3-355

$8,786.79

Free Shipping

Quantity

Features

• SKU: A720HG3-355

• Input phase: 3 phase

• Input voltage: 380V ± 15%

• Input frequency: 50/60Hz

• Control method: V/F, SVC

• Braking Resistor: 3.8Ω/19000W * 3

• HS Code: 8504409940

• Size: 1250*800*450mm

• Output phase: 3 phase

• Output voltage: 0 - 380V

• Output frequency: 0 - 400Hz (low mode)

• Output frequency: 0 - 3200Hz (high mode)

• Output current: 0 - 650A

• Output power: 0 - 355kW (476HP)

Terminals and Wirings

(Main Loop)

• R, S, T: connected to 3-phase AC power supply 380V

• U, V, W: connected to the three-phase motor

• PE: grounding connection

• PE: grounding connection

• P+, PB: connected to the brake resistance

(Control Loop)

• X1 - X5: multifunction digital input terminals; effective when closed to COM; function is defined by Parameters P4-00 to P4-04

• X6: similar to X1-X5; also as high-speed pulse input terminal, see Parameters P4-28 to P4-32

• Y: can be high-speed pulse output; also can be collector output; see Parameters P5-00 and P5-09

• AI1: analog input 1; voltage, 0-10V, input impedance 100kΩ; current, 0-20mA, input impedance 500Ω; Jumper CN400 determine voltage or current input mode

• AI2: analog input2; voltage, 0-10V, input impedance 100kΩ

• AO1: analog output 1; voltage, 0-10V; current, 0-20mA; Jumper CN504 select voltage or current output mode; see Parameter P5-07

• TA1, TB1, TC1: multifunctional relay output 1, defined by Parameter P5-02

• TA2, TB2, TC2: multifunctional relay output 2, defined by Parameter P5-03

• +24V: power source for digital input terminals X1-X6

• +10V: power source for analog input terminals AI1 and AI2

• COM: reference ground for digital input terminals X1-X6

• GND: reference ground for analog input terminals AI1 and AI2

• 485+, 485-: standard RS485 communication port; please use twisted pair cable or shielded cable

A720HG3 Control Panel

Key PRG: enter programming mode, or return to the parent menu

Key ENTER: enter the sub menu, or confirm parameter values

Key ▲ : increase function code, menu group, or parameter value

Key ▼ : decrease function code, menu group, or parameter value

Key ⏩ : shift display parameters in monitoring mode, or change the data bit in programming mode

Key RUN: start the motor under keypad mode

Key STOP : stop the motor under keypad mode, or reset the fault alarm state

Key FUNC : switch functions based on Parameter P7-01

Indicator ALM : on indicates a fault; flashing indicates an alarm

Indicator F/R: on for reverse rotation; off for forward rotation; flashing when the VFD and motor rotate in opposite directions

Indicator RUN: on when the running frequency reaches the set value; off when the inverter is stopped; flashing during acceleration or deceleration

Indicators Hz, A, V: units of frequency, current, and voltage

How to Start, Stop and Reverse Motors